375L SINGLE PUMP FIXED CAT 5 BOOSTER S

375L SINGLE PUMP FIXED CAT 5 BOOSTER SET
Cold water booster pump set for improving mains water pressure in domestic and commercial properties.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Direct Pumps & Tanks
What makes this SET the right choice?
375L SINGLE PUMP FIXED CAT 5 BOOSTER SET
The CAT 5 booster set also know as Backflow prevention booster set incorporates a 375 Litre GRP WRAS approved break tank complete with a raised ball valve chamber with an AB air gap to WRAS approved regulations.
APPLICATIONS INCLUDE:
- Laboratories
- Veterinary Surgeries
- Bin Washdown
- Mortuaries
- Abattoirs
- Bib Tap
OPERATION:
The CAT 5 Booster set is designed to monitor the system pressure. As the demand increases the pressure will fall and the pump will start to run until the demand has stopped and the pressure increases.
PUMP SPECIFICATION:
Multistage pump complete built in pressure switch, 230 volt single phase supply.
TECHNICAL SPECIFICATIONS:
- Single Pump Packaged Booster Set and CAT5 Break Tank.
- Fixed Speed Pressure Pump - Variable speed optional upon request.
- Pre-assembled for easy installation.
- Wet/Pressure tested prior to despatch.
- Quiet operation, less than 50 decibels.
- Compact design, narrow width ideal for access through doorways.
- WRAS Approved water storage tank manufactured from GRP with 25mm insulation.
- WRAS Approved 3
- 4" High flow ball valve fitted.
- 1 Phase 230 Volt supply.
- Low Water Level Protection.
- WRAS Approved fully adjustable system pressure reducing valve fitted.
- Maximum allowable static head 12 metres.
Technical data
Full specifications
| Physical | |
| L × W × H | 67 × 61 × 184 cm |
| L × W × H (mm) | 670 × 610 × 1840 |
| Reference | |
| SKU | CAT5/S/375 |
| EDEL code | EDELP00002097 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.