ARMORGARD SAFESTOR

ARMORGARD SAFESTOR
The Safestor is purpose-built for the indoor safe storage of flammables and chemicals, including paint and other hazardous substances.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Armorgard Ltd
What makes this SAFESTOR the right choice?
ARMORGARD SAFESTOR
The medium-duty hazardous substance cabinet that complies with all COSHH regulations. The Safestor is purpose-built for the indoor safe storage of flammables and chemicals, including paint and other hazardous substances. Fully compliant with all legislation relating to the control of substances hazardous to health (coshh), This robust range of cabinets features a liquid-tight sump to contain spillages, as well as galvanized shelves for maximum durability.
Specification:
- Galvanized shelves
- Reinforced doors
- Flush handles with two-point locking
- Powder coated paint finish - complete with relevant warning signs
- Meets relevant regulation for storing fuel or chemicals
- Liquid-tight sump to contain spillages
- Built to specification for 1/2 hour fire resistant
Sizes:
- Safestor HFC1 c/w 1 Shelf - 900mm W x 465mm D x 700mm H - Weight 21kg
- Safestor HFC2 c/w 1 Shelf - 350mm W x 315mm D x 700mm H - Weight 13kg
- Safestor HFC3 c/w 1 Shelf - 900mm W x 465mm D x 900mm H - Weight 28kg
- Safestor HFC4 c/w 1 Shelf - 450mm W x 465mm D x 905mm H - Weight 31kg
- Safestor HFC5 c/w 2 Shelves - 900mm W x 465mm D x 1200mm H - Weight 41kg
- Safestor HFC6 c/w 3 Shelves - 1200mm W x 465mm D x 1800mm H - Weight 68kg
- Safestor HFC7 c/w 3 Shelves - 900mm W x 465mm D x 1800mm H - Weight 55kg
Technical data
Full specifications
| Physical | |
| Empty weight | 21 kg |
| Reference | |
| SKU | HFC1 |
| EDEL code | EDELP00002081 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.