ESBE 3-POINT MIXING / DIVERTING ACTUAT

ESBE 3-Point Mixing / Diverting Actuator
In these applications can any position of the actuator operating range be used to get the desired mix level.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Kingspan Parts
What makes this Actuator the right choice?
ESBE 3-Point Mixing / Diverting Actuator
The ESBE Series ARA600 with 3-point (open/close) signal is a compact actuator suitable for mixing operations together with valves such as VRG130. In these applications can any position of the actuator operating range be used to get the desired mix level. The compact actuator is designed for operating rotary valves DN 15-50 and has an operating range of 90°. The series can easily be manually operated by the pull-and-turn knob on the front of the cover. Auxiliary switch, available as premounted, can be set in any position and is easily set by a unique solution.
- Reliable and quiet operation.
- Assortment for any need.
- Perfect match between the actuator and ESBE valve.
Specification:
| Reference | Voltage (VAC) | Running time 90° [s] |
Control Signal | Torque (Nm) |
| ARA652 | 24 | 60 | 3-point SPDT | 6 |
| ARA664 | 24 | 120 | 3-point SPDT | 6 |
| ARA662 | 24 | 120 | 3-point SPDT | 6 |
Technical:
| Power supply: | 24 ± 10% V AC, 50 Hz; 230 ± 10% V AC, 50 Hz |
| Power consumption: | 24V: 3 VA; 230V: 5 VA |
| Enclosure rating: | IP41 |
| Protection class: | II |
| Torque: | See dimension table |
| Rating auxiliary switch: | 6(3) A 250 V AC |
| Weight: | 0,4 kg |
| Ambient temperature, max.: | +55 °C |
| Ambient temperature, min.: | -5 °C |
Technical data
Full specifications
| Reference | |
| SKU | 12101800 |
| EDEL code | EDELP00366454 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Technical documentation
Downloads & data sheets
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.