FULL RETENTION SEPARATOR NSFP6

FULL RETENTION SEPARATOR NSFP6
This is normally equivalent to the flow generated by a rainfall intensity of 65mm/hr.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Klargester (Ac)
What makes this NSFP6 the right choice?
FULL RETENTION SEPARATOR NSFP6
Our full retention separators or petrol interceptors can be used in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts. Full retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by a rainfall intensity of 65mm/hr.
Each full retention separator design includes the necessary volume requirements for:
- Oil separation capacity
- Silt storage capacity
- Automatic closure device
- Oil storage volume
- Coalescer (Class 1 units only)
- Full alarm range available
Features and benefits
- Designed for easy installation, saving you time and money
- Certified to EN858 - 1 for complete peace of mind
- Class 1 and Class 11 design
- Inclusive of silt storage volume
- Extension access shafts for deep inverts
- Oil alarm probe tube available (required by EN858-1)
- Fitted inlet/outlet connections
- Vent points within necks
- Maintenance from ground level
- Polyethylene Chamber Construction - light, high strength and durability
- CE-marked in line with the CPR 2013
Specification
- Flowrate 6 l/s
- Drainage area - 335m2
- Storage Capacity (litres) - Silt 600l / Oil 60l
- Base to invert level - 1420mm
- Base to outlet level - 1345mm
- Min. Invert Inlet - 500mm
- Standard pipework diameter - 160mm

![]()
*DELIVERY TERMS
All tanks are delivered on 45ft Flat-bed Articulated Trailers, so off-loading equipment on site is necessary.
HIAB off-loading is available at extra cost, if requested.
It is the responsibility of the customer to inform us, if off-loading equipment is required.
DO YOU REQUIRE COMMISSIONING?
To ensure your system operates to maximum efficiency, we recommend tried and tested commissioning by Klargesters own trained engineers.
Our unrivalled knowledge means that we are best placed to carry out bespoke assessments to get your system up and running. The commissioning will also provide you with a unique checklist against your system, ensuring your complete peace of mind and reassurance that your system's mechanical and electrical components are in good working order.
WHAT'S INCLUDED IN THE COMMISSIONING? CLICK HERE FOR MORE INFORMATION
Service and Maintenance:
It is essential that you ensure your separator is properly serviced and maintained to remain compliant with EN 858-1 standard and prevent pollution due to blockages. Kingspan's service and maintenance packages have been developed using their expert knowledge of their separators to help keep your separator operating at optimal efficiency, therefore remaining non-polluting and compliant. Visit Kingspan Service or contact the Kingspan Team on 0818 543 500 or for more information on the packages available.
Technical data
Full specifications
| Reference | |
| SKU | 0014352 |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Technical documentation