3000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided

Product Ref: PW.1.5x1x2.IFB-AG.DIV (1+0.5)

Water Made To Order GRP Non-returnable Customer Off Loading, Free Delivery Customer Off Loading, Free Delivery Twin WRAS Approved

€POA
Request a quote

Product Description

3000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided

3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.

What's the Divided Section for in a sectional tank?

Tanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.

Please note: divided tanks are essentially two separate tanks & therefore require double the quantity of connections, i.e. 2 x inlet connections & 2 x outlet connections to the down services.  

Insulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included.

IFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. 

IFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and/or 350 mm above any raised float valve housing. 

Optional Extras:

Screened lid vent
Screened overflow ¾' (22 mm) up to 4" 
Screened warning pipe ¾' (22 mm)
BSP female tank connector 1" up to 4" 
Lid mounted level switch to suit high or low warning Temperature sensor

Important: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation. 

An Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.

Applications where there is sufficient working room all around the tank.

Comprising: Internally flanged base, externally flanged sides, internally flanged roof. 

Insulated to the sides and cover only.

 

Specification

  • Insulation: 50 mm Fully Encapsulated to Sides
  • Panel Size: 1000 x 1000 mm
  • Side Panels: Externally Flanged
  • Base Panels: Internally Flanged
  • Heavy Duty Lid: Internally Flanged
  • Internal fixings: Stainless Steel
  • External fixings: Galvanised
  • Man way: Included, providing 800 x 800 mm access opening
  • 1 x 1 x 2 & 0.5 x 1 x 2 high compartments (divided sections)
  • Foundation Levelling Steels:  Included (To suit flat structural foundation pad)

 

PW.1.5x1x2.IFB-AG.DIV (1+0.5) Dimensions

 Airgap  AG
 Single or twin compartment (Divided) Twin - 1 x 1 x 2 & 0.5 x 1 x 2 m
 External Dimensions 1650 x 1150 x 2250 mm high
 Assembly area required 2650 x 2150 x 2750 mm high

Product Specification

  • Product Code: PW
  • Fuel Type: Water
  • Made To Order: Made To Order
  • Material: GRP
  • Non-returnable: Non-returnable
  • Shipping: Customer Off Loading, Free Delivery
  • Twin or Single: Twin
  • WRAS Approved: WRAS Approved
  • Volume: 3000ltr
  • Dimensions: L:1650mm W:1150mm H:2250mm

Delivery Terms

Kingspan Tanks - Tail-lift deliveries are available for most tanks up to 2,000 Litre capacities for kerbside delivery.
It is the responsibility of the customer to inform us, if off-loading equipment is required.

Klargester Tanks  - All tanks are delivered on 45ft Flat-bed Articulated Trailers, so off-loading equipment on site is necessary.
HIAB off-loading is available at extra cost, if requested.
It is the responsibility of the customer to inform us, if off-loading equipment is required.

Harlequin Tanks  - Tail-lift deliveries are available for most tanks up to 2,500 Litre capacities for kerbside delivery subject to availability.
It is the responsibility of the customer to inform us, if off-loading equipment is required.

tanks.ie undertakes to attempt to fulfill all orders within a maximum of 7 working days of order acceptance, unless advised otherwise. In the event that any order is delayed, tanks.ie will not be responsible for any consequential loss or damage that this delay may cause.

Smaller items (including most accessories and consumables) will normally be despatched by courier.
Larger items (including all storage tanks) will normally be delivered by carrier. 

Please note that for all items delivered by carrier, normally a truck + 40ft trailer, it is the customer's responsibility to ensure adequate vehicular access and to provide suitable offloading equipment, where required. Please notify us, if this might pose a problem and we will endeavour to facilitate your request. 

Returns Information

ORDER CANCELLATION 

In accordance with Irish and European Union consumer laws, you have seven days after receipt of order to cancel the order in its entirety or any part thereof, providing the goods are in a re-saleable condition. Should you wish to cancel any order, you must first contact sales@tanks.ie for a ‘Returns Authorisation Number’.

Please call 051 351325 or e-mail sales@tanks.ie 


After the Returns Authorisation Number has been issued, we will make arrangements with you for the goods to be returned. If you wish tanks.ie to arrange the collection of the goods, please note that a carriage and administration charge will apply, which will not exceed 35% of the gross value of the goods.

Upon return of the cancelled goods to tanks.ie and verification that they are in a re-saleable condition, we will refund the value of the goods, less any collection and administration charges, within 28 days.

DEFECTIVE PRODUCTS 

If you believe that products you have purchased from tanks.ie are defective, please report this immediately to tanks.ie by e-mail sales@tanks.ie or call 051 351325. 

If they are within the manufacturer’s guarantee period, we will arrange with the manufacturer to replace or repair the goods at the manufacturer’s discretion and consistent with their guarantee. 
Where it is necessary to inspect the goods on site and an inspection proves the fault is neither the fault of tanks.ie, nor the product manufacturer, an inspection charge will apply, which will be advised by the manufacturer prior to site inspection.

Please note that where guarantees are available in excess of those required by law, these are provided at the discretion of the product manufacturer and not tanks.ie. Additionally, tanks.ie will not be liable for any claims for consequential damage or loss. 